型号/MODEL
|
JH-0.3
|
|
描述/Description
|
制氢量≤1Nm³/h, 具有高压力低露点 ,提供氢燃料电池所需的高品质氢气。
Hydrogen production capacity ≤1Nm³/h, with high pressure and low dew point, to provide high-quality hydrogen required for hydrogen fuel cells.
|
制氢能力/HYDROGEN PRODUCTION
|
标况速率/
Ntional Production Rate
|
0.3Nm3/h
0.6Kg/24h
|
|
电解槽额定功率/ Rated Power of Electrolyzer
|
1.3kW
|
|
能耗/
Energy Consumption
KWh/Nm3@1.5A/cm2
|
4.6 kWh/Nm3
51 kWh/kg
|
输氢压力/Delivery Pressure-Nominal
|
3MPa
|
纯度/Purity
|
>99.995%
H2O < 10ppm,O2 < 2ppm, N2 < 2ppm
|
露点/Dew Point
|
< -40℃
|
调节范围/Turndown Range
|
0% ~120%
|
电气规格/ELECTRICAL SPECIFICATIONS
|
电力需求/Electrical Requirements
|
单相交流210V~240V,50Hz
210 to 240VAC,single phase,50Hz
|
最小需求功率/Minimum Power Required
|
1.5 kVA
|
|
供水要求/WATER REQUIREMENTS
|
最大耗水量/Consumption Rate at Maximum Production
|
0.3L/hr
|
|
水质要求/Water Quality
|
> 1MΩ·cm(<1μS/cm)
|
水温/Temperature
|
5 ~ 50℃
|
水压/Pressure
|
0.5~2 barg
|
冷热要求/HEAT LOAD AND COOLANT REQUIREMENTS
|
冷却/Coolant
|
风冷/Air-cooled
|
连接接口/INTERFACE CONNECTIONS
|
产氢接口/
H2 Product Port
|
DN6
|
氢/水排水接口/
H2/ H2O Vent Port
|
DN6
|
氧气排气口/
O2 Vent Port
|
DN10
|
进水接口/DI Water Port
|
DN10
|
排水接口/Drain Port
|
DN10
|
电气接口/Electrical
|
三孔插头/Three-Prong Plug(Less than 2.5kW)
单相断路器/ Single-phase circuit breaker (More than 2.5kW)
|
通讯接口/ Communication Interface
|
RS485串口
|
控制系统/CONTROL SYSTEMS
|
控制/Control
|
PLC
|
工作模式/ Work Pattern
|
1.网电供应运行/ Grid power supply operation
2.可再生能源供应运行/ Renewable energy supply runs
|
标准特性/Standard Features
|
一键启停、超压报警 、缺水报警 、水满报警、超温报警 、氢气泄漏报警 、水质检测报警
One-button start and stop, overpressure alarm, water shortage alarm, water full alarm, overtemperature alarm, hydrogen leakage alarm, water quality detection alar
|
物理特性/PHYSICAL CHARACTERISTICS
|
尺寸/Dimensions
L*W*H
|
600*330*530
|
800*430*630
|
|
重量/Weight
|
45kg
|
65kg
|
|
IP 评级/IP Rating
|
IP22
|
运行环境建议/ENVIRONMENTAL CONSIDERATIONS
|
标准位置/Standard Siting Location
|
室内、水平摆放±10、湿度≤90%无冷凝
Indoor,level±10,0 to 90%RH non-condensing
|
工作环境温度/Ambient Temperature Range
|
1 ~ 60℃
|
工作海拔/Altitude Range – Sea Level
|
≤2000m
|
房间通风/Room Ventition
|
需要从安全风源位置提供适当通风
Proper ventilation from a safe air source location is required
|
其他
|
噪音 (一米距离)
Noise(1meter)
|
<55 dB(A)
|
附带功能/ Incidence Function
|
氮气吹扫、气干燥、纯化、氢气露点监测、氢气泄漏监测、水超纯化处理、水箱液位监测、电解水水质监测 Nitrogen purge, gas drying, purification, hydrogen dew point monitoring, hydrogen leak monitoring, water ultra-purification treatment, water tank level monitoring, electrolytic water quality monitoring
|